For period homes
Nothing gets cut into the cornice.
The stone houses of the Cotswolds and north Wiltshire were built with no thought of air conditioning, and a great many are protected. It can still be done, and done properly, if it’s thought through first.

Before anything else
Which is your house?
What a house is protected by decides where the outdoor unit can go, and what needs consent. Choose yours to see what each place needs.
If more than one is true, choose the first.
At the back or side, usually no application. At the front, it needs one.
- 1In the back gardenUsually no applicationIf it meets the size limit and the noise test.
- 2Against a side wallUsually no applicationAs at the back, unless that side faces a road.
- 3At the front, facing the roadNeeds an applicationOn a wall facing the road, or nearer the road than the house.
- 4Inside the houseNo listed building consentIt isn’t listed, so the inside needs none.
The same rule applies in a World Heritage Site, such as Stonehenge and Avebury. The back or side is where we’d put it anyway.
Wherever it goes: the unit must heat as well as cool, and pass a 37 dB noise test at the neighbour’s nearest window. Not sure which your house is? We look it up before we quote.
A plain summary for England, not legal advice. Planning permission and listed buildings, in full.
The indoor unit
One room, three ways.
In a room with a cornice, the unit should leave the room as it was built. We’ll mark each option on your own wall before anyone drills anything.



As most go in
The stone, and the pipes
One hole, in the right place.
Two small pipes and a cable have to get from the room to the outdoor unit, and in most houses that means one hole about 65 mm across. A hole through Cotswold stone is a bigger decision than a hole through brick. We go along joints rather than through faces where we can, and make good in lime.
Inside, we use cupboards, voids and walls that have already been altered, and we show you the whole route before we start.

How it goes
Four steps, and no sales call.
Questions
What people ask about an old house
Will I need planning permission?
Often not on a house in England, if the unit also heats and meets the national limits, including a 37 dB noise test at your neighbour’s window. Listed buildings usually need consent, conservation areas have stricter siting rules, and the old centres of towns like Malmesbury, Cirencester and Tetbury are full of both. We check before we quote. More on this
Can you do this in a listed building?
Sometimes, and it needs care. Historic England says indoor units can sit low like a radiator, or chassis versions can go in ceiling voids or a decorative enclosure that matches the interior. Anything that affects the building’s character is likely to need listed building consent. More on this
Can’t you just box in a wall unit?
We won’t. No maker we’ve read describes or allows for an enclosure around a wall unit. They all say to keep the air inlet and outlet clear, and the filter has to come out. A closed box can cut its performance and leave the engineer no way in, and Daikin says it won’t remove cupboards, kitchen units or trims to reach a unit for a warranty repair. If you want a wall unit to look different, we change the unit.
Do I actually need to hide it?
Perhaps not. Historic England looked at heat pumps in ten small historic properties and then five larger buildings, and found that visual and noise impact wasn’t an issue for the people using them. Plenty of gardens only need the unit moved a few metres. We’ll tell you if yours is one of them.
How much mess does it make?
One hole through the wall, about 65 mm across, usually hidden behind the indoor unit, and a neat run of pipe outside. We sheet the floor, vacuum as we go and take the packaging away. More on this