See my price

The indoor unit

Can’t see it. Can’t miss it.

It doesn’t have to be a white box you put up with. It can sit behind a slim grille, settle into your paint or be the best-looking thing in the room. Here’s one room, and four ways to lose it.

A sitting room in a Cotswold stone house, with a plain white air conditioning unit high on the wall above the sofa, a landscape painting, a panelled window seat and a standard lamp
The same room with nothing on the wall, and two slim grilles set flush into the ceiling above the sofa
The same room with nothing on the wall, and a flat square white panel set into the ceiling
The same room with nothing on the wall, and a slotted grille in the panelled front of the window seat, with a slim one along its back against the window
The same room with a slim pale console set low into the wall to the right of the sofa, like a shallow radiator

As most go in

See my priceOr make it stand out

Make it disappear

What each one really takes.

All of them cost more than a wall unit, and most mean building work. We’d rather you knew that before you fell for one.

  1. Above the ceiling

    Ducted

    One of the two slim grilles in the ceiling, close up, just out from the cornice
    What shows
    Slim grilles, and nothing else
    What it needs
    A ceiling void of at least 240 mm for Daikin’s FDXM. Mitsubishi’s SEZ-M can fit about 230 mm, but only with a removable panel around 777 by 800 mm under it. A drain with a fall, and a way for the air to come back.
    The catch
    The most building work, so it suits a renovation. Both makers’ manuals also show at least 2.5 metres from the floor to the unit, and neither says whether that still applies behind a ceiling, so we’d ask them before promising a low room.
  2. In the ceiling

    Cassette

    The square ceiling panel, close up, with a slot along each side
    What shows
    A flat square panel, about 620 mm across
    What it needs
    A void from 250 mm for Mitsubishi’s SLZ-M to 300 mm for Daikin’s FFA, and a hole in the ceiling. Both have a drain that lifts the water away.
    The catch
    Tidy, but you can still see it, and the same 2.5 metre rule applies. Mitsubishi’s UK sheet pitches this one at offices and shops, so it’s not the look for every home.
  3. Inside the joinery

    Concealed floor unit

    The window seat close up, with a slotted grille in its panelled front and a slim one along its back
    What shows
    A grille in a window seat or panelled front
    What it needs
    Daikin’s FNA is 790 mm wide, 620 high and 200 deep, and it has to go in a fully enclosed casing. The front must come off with a tool, and for a 2.5 kW unit Daikin’s drawing marks a maintenance area 1,350 mm wide.
    The catch
    The best answer in a period room, and Historic England names decorative enclosures as an option. But it needs a good joiner and a wall with the width to spare.
  4. Half in the wall

    Floor console

    The console close up, low on the wall above the skirting, standing only a little proud of the plaster
    What shows
    A shallow front, like a slim radiator
    What it needs
    Daikin’s Perfera floor unit has a half-concealed layout, with a wall opening about 740 by 595 mm. By our reading of the drawing, roughly 159 of its 238 mm goes into the wall.
    The catch
    You need a wall you can cut into, so it’s rarely for a listed one.

What we won’t do is build a box round a wall unit.

No maker we’ve read allows for it. The air has to get in and out, the filter has to come out, and the engineer has to get to it. If you want a wall unit to look different, we change the unit.

Make it stand out

Or let it be the best thing in the room.

These are the makers’ own, as they come. Press one to hang it in the showroom against your paint.

A pale limewashed sitting room in a Cotswold stone house, with a Daikin Emura in matt black on the wall above a linen sofa
Daikin Emura in matt black, at its real size. The unit is Daikin’s own picture; the room is ours, and it’s only there to show its size.

Questions

What people ask about the indoor unit

Can’t you just box in a wall unit?

We won’t. No maker we’ve read describes or allows for an enclosure around a wall unit. They all say to keep the air inlet and outlet clear, and the filter has to come out. A closed box can cut its performance and leave the engineer no way in, and Daikin says it won’t remove cupboards, kitchen units or trims to reach a unit for a warranty repair. If you want a wall unit to look different, we change the unit.

Which is the most invisible?

Ducted, above the ceiling, because only grilles show. But it takes the most building work, it needs a void and a route for the drain, and there has to be a panel we can always open. In a room you’re not otherwise altering, a slim wall unit in the right finish, in the right place, is usually the better answer.

Can you do this in a listed building?

Sometimes, and it needs care. Historic England says indoor units can sit low like a radiator, or chassis versions can go in ceiling voids or a decorative enclosure that matches the interior. Anything that affects the building’s character is likely to need listed building consent. More on this

Does hiding it cost more?

Yes. Floor consoles and ducted units cost more than wall units, and the published guides for ducted work range so widely that we wouldn’t quote one. You’ll get a written price after we’ve seen the room. More on this

Will a bold colour date?

It might, in the way that any bold choice can. Toshiba’s cloth cover is the safest bet, because it can be changed. Otherwise pick the one you’ll still like in years to come, because you’ll be looking at it for a long time.

NextAnd the one outside? We make it disappear.