See my price

How noisy it is

How noisy is air conditioning?

The short answer

Indoors, a good wall unit runs at about 19 dB on its lowest speed, which is quieter than a whisper at about 30 dB. On its top speed it’s 40 to 45 dB, which you’ll certainly hear. The outdoor unit is louder, at around 46 to 49 dB, so where it goes matters most.

About 1 minute to read6 sources, named belowA noise scale insideChecked 5 November 2026

  • A good indoor unit, lowest speed19 dB
  • A whisper30 dB
  • The planning limit at a neighbour’s window37 dB
  • A good indoor unit, top speed40 dB
  • An outdoor unit, on its spec sheet47 dB
Decibels don’t add up in a straight line: 10 dB more sounds about twice as loud. The planning figure and the spec sheet figures aren’t measured in the same way.

Indoors

A unit only runs at full speed when it’s catching up. Once a room is at temperature it slows down, and a night setting holds it at the lowest speed. So the number that matters in a bedroom is the bottom of the range.

Outdoors, and your neighbours

For a unit to count as permitted development, the sound at a point a metre from a neighbour’s habitable window must come to 37 dB or less, by the MCS calculation. That uses the unit’s sound power, about 57 to 60 dB for a 2.5 kW unit, which isn’t the same number as the brochure’s sound pressure figure. It’s why position and a solid screen matter more than the model.

ModelIndoors, lowest to highestOutdoors
Daikin Stylish19 to 4046 cooling, 47 heating
Daikin Perfera19 to 4146 cooling, 47 heating
Mitsubishi Electric MSZ-LN19 to 4246 cooling, 49 heating
Mitsubishi Electric MSZ-AY18 to 4247 cooling, 48 heating
Toshiba Shorai Edge19 to 40Up to 44 cooling, 46 heating
Published figures for 2.5 kW models, in dB(A). Makers don’t all use the same conditions, so compare with care.

Sources

  1. Daikin Stylish product flyer, 2023
  2. Mitsubishi Electric MSZ-LN UK brochure, February 2026
  3. Toshiba Shorai Edge data sheet
  4. US CDC: general estimates of noise levels
  5. MCS 020 a), the planning noise standard
  6. Approved Document O (overheating), paragraph 3.3

Last checked 5 November 2026.