Heating in winter
Does air conditioning work in winter?
The short answer
Yes. Most units are rated to heat down to about −15°C, and some to −21°C or −25°C, which is well below a normal winter here. Output and efficiency do fall as it gets colder, and the unit will pause now and then to defrost itself.
- Daikin Stylish−15°
- Toshiba Shorai Edge−15°
- Mitsubishi Electric MSZ-LN−15°
- Daikin Perfera−21°
- Mitsubishi Electric Hyper Heating−25°
What happens in a frost
The outdoor coil runs colder than the air, so frost can form on it. Every so often the unit reverses for a few minutes to clear it, and no warm air comes from the indoor unit during that time. A hiss, or a white mist from the outdoor unit, is normal.
How cold it gets here
The design temperatures used for sizing heating are about −3°C to −5°C at Birmingham and −1.5°C to −3°C at Cardiff, the nearest cities in the standard. So a unit rated to −15°C has plenty in hand, and what matters is whether it’s sized to give enough heat at those temperatures.
Is it cheaper than what I have?
It’s far cheaper than plug-in electric heat: about a fifth of the cost on test figures. Against a gas boiler it’s closer: on a modest load, about half the cost on test figures, and about the same on cautious real-world figures. So it’s strongest for the rooms the boiler doesn’t reach, or as a way of heating one room without firing up the whole house.
Sources
- Daikin Stylish product flyer, 2023
- Mitsubishi Electric MSZ-LN UK brochure, February 2026
- Government literature review of air-to-air heat pumps, March 2025
- Daikin user reference guide: defrost
- MCS heat pump design standard MIS 3005-D
- Ofgem: energy price cap rates, 1 October to 31 December 2026
Last checked 5 November 2026.